Drivers Weilekes Elektronik Port Devices



Right-click PCI Device, which will have a “!” or “?” next to it to indicate a driver issue, and click Update Driver. Click Browse my computer for driver software. Click Let me pick from a list of device drivers on my computer check box. On the Select your device’s type from the list below screen, click Show All Devices, and click Next. Port is a market leading company in the field of protocol libraries. Stacks, drivers and tools for industrial real time communication. Since 1990 our Know-How accelerates your Time-To-Market. More than 500 customers worldwide and thousands of devices using port`s real time technology successfully. ConBee Installation. The deCONZ application is a tool to configure, control and monitor Zigbee networks with the ConBee. The following sections describe the installation steps of deCONZ for various platforms. USB Driver MiniLog2 Version 6.6 32 / 64 bit Driver for Win XP, Vista, Win 7 and Win 8:: 3.517 MB. In the menu 'Extras' - 'Options' the IP adress and port of the proxy server as well as the user name and password have to be entered. Weilekes Elektronik GmbH Am Luftschacht 17 45886 Gelsenkirchen (Germany) +49 209 170 80-0 info. I have reinstalled drivers, unplugged and replugged the stick, restarted the NAS, still nothing. When i try the lsusb i get: Bus 001 Device 002: ID 10c4:8a2a Cygnal Integrated Products, Inc. Bus 001 Device 003: ID f400:f400 Bus 001 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 002 Device 001: ID 1d6b:0003 Linux Foundation 3.0 root hub.

With our innovative, patented technologies, we make signal conditioning smarter and simpler. Our portfolio is composed of six product areas offering a wide range of analog and digital modules covering over a thousand applications in industrial and factory automation.

All our products comply with or surpass the highest industry standards, ensuring reliability in even the harshest of environments and have a 5-year warranty for greater peace of mind.

Transmitters and sensors - analog, bus or digital communication

Intrinsically safe isolated barriers and backplane solutions (SIL 2)

Detachable local or remote operator interfaces, etc.

Wide range of input/output - multiple applications

Drivers weilekes elektronik port devices inc

Compact, fast 6 mm isolators with exceptional performance

Complete range of panel meters

Devices for special applications.

Drivers weilekes elektronik port devices downloadDrivers Weilekes Elektronik Port Devices

A range of accessories that complement our devices.

This USB hub has six USB downstream ports with quick USB 3.0 standard that can be turned on and off individually via USB. Due to USB 3.0 integration, the data transfer rate will increase tremendously compared to the USB 2.0 standard.

The USB hub is operated using a 12...24 VDC power supply with at least 35 W output power, which is sufficient for a 900 mA output current on each USB port.

The USB ports have a function to detect when a USB device is connected. This also works for connected devices that only use the power from the connection (such as USB fans or reading lights). Connection detection can be disabled individually for each port if the small test current should lead to unexpected problems. When switching it off, the supply voltage (+5 V) and the data lines on the semiconductor switches are separated. The control is via ASCII commands or the Toolmonitor USB hub (PC software), which is included in delivery in the form of an USB memory stick. Whether or not and which ports are active after switching on the hub can all be configured and stored. The USB 3.0 host connection is usually also used to control the USB hub. Alternatively, however, control can also be provided from another host using the additional USB 2.0 connection on the back. In addition to this control via USB, ports can alternatively also be turned on and off via external control inputs.

The ports switch to the configurable default state during connecting the external power supply. The connection for the external power supply is a DC connector. COM/DCOM or a .Net-Assembly is used as an interface. This allows the Toolmonitor USB hub to be integrated in a large number of applications (MCD TestManager CE, LabView®, Microsoft Visual Studio® (C#, C++, Visual Basic), Microsoft Office® (e.g. Excel®), OpenOffice®). Control via virtual serial interface is also possible. There is also a command-line tool available. Furthermore, the USB hub 3.0 6-Port can also be implemented for Linux operating systems, if required.

  • USB 3.0 host connection to control downstream ports individually
  • 6 ports, individually switchable with up to 2.5 A per port, total output current up to 6 A
  • Each port is protected by a resettable overload breaker
  • Current limitation adjustable, connected devices are protected from excess current by the adjusted shutoff limit
  • Adjustable charger emulation for many mobile devices (such as CDP, DCP, etc.), automatic mode tries different profiles
  • Detection of whether a device has been connected to a port and detection of connection of none-USB devices (such as USB fans, USB reading lights, etc.)
  • Current measurement for every port (resolution about 10 mA): detection of defects (e.g. current consumption too high / too low), measurement of the current consumption of connected devices
  • Display for port/channel: on / off / excess current / charge / charge complete / no device connected (mode always visible from outside)
  • On and off via USB ports
  • Separation of power supply and data lines by a turned-off port
  • LEDs to indicate switched ports
  • Control via Toolmonitor USB-Hub
  • Control via the USB hub connection or an additional USB control connection (hub functionality and control of the USB hub with just one cable), alternatively supports connection of the hub to a host (e.g. an embedded host) with simultaneous control from another host (such as a PC)
  • Permits control via external control elements like switches, relays, open collector outputs and control voltages from 0 V (low) and 2.5 ... 24 V (high), polarity (active low / active high) and priority (parallel input / control via USB) individualy configurable for each port
  • Back feed from the power supply to the USB host
  • Robust metal housing
  • User-defined labeling of USB hub to distinguish from other USB hubs on the controlling host
  • Remote control with a lot of operating systems or programming languages via ASCII commands
  • Incl. power supply with DC power connector (screwable)
  • Installation package with all programming interfaces

USB hub 3.0 6-Port, switchable (2 control inputs)
Order number: 153780

USB hub 3.0 6-Port,
2 control inputs, switchable

exe-Datei | 27 MB
Version 3.4.2.11 - 14.03.2019

Manual USB-Hub 3.0 6-Port,
2 control inputs

pdf-Datei | 1.6 MB
manual-usb-hub-3.0-6-port-mcd.pdf

If there should be problems during the driver installation, find current driver updates here.

Flyer USB hub 3.0 6-port

Drivers Weilekes Elektronik Port Devices Inc